Performance & Characteristics
l It is suitable for all liquid flow test of conductivity of greater than 5. Conductivity change does not affect the performance of the change.
l The flow meter has the long-term high accuracy of measurement. It actually is not affected by fluid physical properties. Measurement accuracy can be up to 1, 0.5.
l The flow meter is with no mechanical and moving parts, usually without maintenance.
l Convenient operation, the flow meter is set automatically according to the scope of 0 ~ 10 m/s, without change of measuring range.
l Because of all the parts in contact with the medium under test, have good corrosion resistance and wear resistance, so the applicability is wide.
l In measuring medium containing oil or to the electrode surface sedimentary cover a layer of conductive material medium, can choose a convertible (scrub) electrode.
l Use advanced excitation algorithm.
l Using the world's most excellent integrated circuit to eliminate the influence of excitation switch and using compensation method of excitation current, finally up to the optimal stability of the product.
l Use high efficiency, high stability and designed the wide input range of multiple sets of the isolating switch power supply.
(DC: 18-36V; AC: 85V-265V).
Have a lot of output interface design, using conveniently:
A) 4-20 mA current output;
B) To set the pulse output;
C) The RS485 interface. Self-check function.
l High-definition main LCD backlight display in Chinese of four lines on a large screen.
l When power off, EEPROM can protect set parameters and total value.
l Provide nonlinear correction function of five sections of sensor
l With functions of automatic operation for average flow rate, easy to calibration of instrument.
Working Conditions
Ambient temperature -20- 55C
Ambient humidity 5% - 95%
Power supply AC220V±10%
Operating power <10 W
Maximum working temperature 70–140C
Technical Parameters
Sensor
Diameter of sensor DN10~ DN600
Connection level Accord with national standard GB/T9119-2000
The fluid conductivity >5us/m
Medium velocity 0-10m/s setting automatically
Electrode form standard interpolation
Electrode material stainless steel 316L
Lining materials PTFE
Measuring temperature - 20-140 C
protection grade Standard IP65
Converter (i.e., secondary instrument)
Shell material shell material
Protection grade explosion-proof type
Normal operating temperature - 10 ~ + 40 C
Storage temperature 0~ +40 C
Using the environment temperature relative humidity 5%-90%
Power supply AC220V -15%~+10%
The power consumption <10W
Load resistance 0-20mA, 250-750 Ohm
Output signal
A) All isolated output current: 4-20 mA.
According to the content
A) Instantaneous show for four decimal point can be mobile
B) Cumulative displayed for 8-bit decimal point can be mobile
Output can be selected by the user, such as output terminal of three way
A) 4 ~ 20 mA
B) The amount of frequency
C) Accuracy of 1.0%
D) Constant current characteristic of 1.0%
E) Power supply:
DC18V-36V DC
AC85V-265V AC
Accuracy
Measuring the flow velocity (m/s)
|
Accuracy
|
1≤V≤10
|
±0.5% of the index value ±0.008m/s
|
0≤V≤1.0
|
±0.5% of the index value ±0.008m/s
|
Flow range
Pipe diameter(mm)
DN
|
Min Flow range(m3/h)
|
Max Flow range(m3/h)
|
10
|
0.0283
|
2.8274
|
15
|
0.0636
|
6.3615
|
20
|
0.1131
|
11.3094
|
25
|
0.1767
|
17.6709
|
32
|
0.2895
|
28.9521
|
40
|
0.4524
|
45.2376
|
50
|
0.7068
|
70.6838
|
65
|
1.1946
|
119.4555
|
80
|
1.8095
|
180.9504
|
100
|
2.8274
|
282.7350
|
125
|
4.41177
|
441.7734
|
150
|
6.3615
|
636.1538
|
200
|
11.3094
|
1130.9400
|
250
|
17.6709
|
1767.0938
|
300
|
25.4462
|
2544.6150
|
350
|
34.6350
|
3463.5038
|
400
|
45.2376
|
4523.7600
|
450
|
57.2519
|
5725.1900
|
500
|
70.6838
|
7068.3750
|
600
|
101.7846
|
10178.4600
|
700
|
138.5402
|
13854.0150
|
800
|
180.9504
|
18095.0400
|
900
|
229.0154
|
22901.5350
|
1000
|
282.7350
|
28273.5000
|
We also have other diameter,please contact us if you need.
Ying