Functions and Features:
1) New appearance , compact size , grasp comfort, weighing only 160g, can easily into a pocket or easily carry.
2) Auto power-saving mode
3) Autoranging tests easier and more quickly ; while reducing the number of rotations Handicaps extend instrument longevity .
4) Data hold function , easier to read the measurement result.
5) Meets IEC61010-1 CATIII 600V safety rating criteria , the user can test a wider range of applications and testing , and testing safer, namely to protect the user's investment , but also to ensure the safe use of personnel and equipment .
6)Fluke SmartStrap ? intelligent magnetic versatile strap (Fluke101kit as standard , Fluke-101 is optional ) specially designed , adsorption, suspension, support, heart used to make the instrument easier to carry and perform tests .
Technical Specifications
All accuracy specifications is one-year, operating temperatures of 18 ° C to 28 ° C, relative humidity of 0% to 90%. Precision expressed as :: ± ([% of reading ] + [ minimum resolution] )
Function
|
Range
|
Resolution
|
Accuracy + / - ( % of reading + minimum resolution)
|
AC voltage v (40Hz-500Hz)
|
6.000V
|
0.001V
|
1% +3
|
60.00V
|
0.01V
|
|
600.0V
|
0.1V
|
|
DC voltage
|
6.000V
|
0.001V
|
0.5% +3
|
60.00V
|
0.01V
|
|
600.0V
|
0.1V
|
|
AC millivolt
|
600.0 mV
|
0.1mV
|
3% +3
|
Diode test
|
2.000V
|
0.001V
|
10%
|
Resistance
|
400.0 ?
|
0.1 ?
|
0.5% + 3
|
4.000 k?
|
0.001 k?
|
0.5% + 2
|
40.00 k?
|
0.01 k?
|
0.5% + 2
|
400.0 k?
|
0.1 k?
|
0.5% + 2
|
4.000 M?
|
0.001 M?
|
0.5% + 2
|
40.00 M?
|
0.01 M?
|
1.5% + 3
|
Capacitance
|
50.00 nF
|
0.01 nF
|
2% + 5
|
500.0 nF
|
0.1 nF
|
2% + 5
|
5.000 ?F
|
0.001 ?F
|
5% + 5
|
50.00 ?F
|
0.01 ?F
|
5% + 5
|
500.0 ?F
|
0.1 ?F
|
5% + 5
|
1000 ?F
|
1 ?F
|
5% + 5
|
Frequency(10Hz-100KHz)
|
50.00 Hz
|
0.01 Hz
|
0.1% + 3
|
500.0 Hz
|
0.1 Hz
|
|
5.000 kHz
|
0.001 kHz
|
|
50.00 kHz
|
0.01 kHz
|
|
100.0 kHz
|
0.1 kHz
|
|
Duty Cycle
|
1% -99 %
|
0.1%
|
1% typ.
|
General Technical Specifications
Maximum input voltage
|
600V
|
LCD Display
|
6000 words refresh rate 3 / second
|
Power supply
|
2 AAA, NEDA 24A, IEC LR03
|
Battery life
|
More than 200 hours
|
Operating temperature
|
0 ° C to 40 ° C
|
Storage Temperature
|
-30 ° C to 60 ° C
|
Operating relative humidity
|
Non-condensing 10 ° C ? 90% at 10 ° C to 30 ° C; ? 75% at 30 ° C to 40 ° C
|
Operating relative humidity range 40 M?
|
? 80% at 10 ° C to 30 ° C; ? 70% at 30 ° C to 40 ° C (Without Consideration)
|
Operating altitude
|
2000 m
|
Storage altitude
|
12,000 m
|
Temperature Coefficient
|
0.1 X (specified accuracy) / ° C (\u003c18 ° C or\u003e 28 ° C
|
Dimensions (H * W * L)
|
130 mm x 65 mm x 27mm
|
Weight
|
160 g
|
IP Rating
|
IEC 60529: IP 40
|
Security Level
|
IEC 61010-1: 600 V CAT III, Pollution Degree 2
|
Electromagnetic interference
|
IEC 61326-1: Class handheld
|
Edited by Miriya