ETCR2000+ Digital Clamp-on Earth Ground Resistance Meter Wide Range 0.01-1200ohm
NEW Type 2000+ Series Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster.
Technical Specifications
Range
|
0.01-1200Ω
|
Resolution
|
0.001Ω
|
Sound and light alarm
|
"beep - beep - beep -" alarm sound, Flashing alarm symbol, By AL key to open, close, set
|
LCD
|
4-digital LCD, 47×28.5mm in length
|
Working temperature
|
-20-55
|
Relative Humidity
|
10-90
|
Explosion-proof mark
|
Exia BT3
|
Shift
|
Automatic Shifting
|
External Magnetic Field
|
40A/m
|
External Electric Field
|
1V/m
|
Single Measurement Time
|
0.5 second
|
Resistance Measurement Frequency
|
1KHz
|
The Measured Current Frequency
|
50/60Hz Automatism
|
Storable Measurement Data
|
99groups
|
Setting Range of Resistance Alarm Critical Value
|
1-199 Ω
|
Protection Level
|
Double insulation
|
Structural Feature
|
In the jaw way CT
|
Power Source
|
6VDC (4 ×5# alkaline battery)
|
Span of Jaw
|
28mm
|
Net Weight (including batteries)
|
1160g
|
Dimension
|
285mm long, 85mm wide,56mm thick
|
Accessories
|
Meter1 PCS Test Ring1 PCS Carrying Case1 PCS
|