Performance Features
l Automated calibration of transducer Zero Offset and/or Velocity ;
l Automated gain,Peak Hold and Peak Memory;
l Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB...);
l Automated switch three staff gauge ((Depth d,level p,distance s);
l 100 independence setup, any criterion can be input freely, we can work in the scene without test block;
l Big memory of 500 A graph.
l Gate and DAC alarm;Acoustic-Optical alarm;
l USB port,communication with pc is easy;
l The embeded software can be online updated;
l Li battery, continue working time up to 12 hours;
l Display freeze;
l Automated echo degree;
l Angles and K-value;
l Lock and unlock function of system parameters;
l AWS D1.1;
l Electronic clock calendar ;
l There are 13 standards of DAC in .
l Automated make video of test process and play; Connect the Upan,the length of video is unlimited
l Two gates setting and alarm indication;
l High-speed capture and very low noise;
l DAC,AVG,TCG,B Scan ; Solid metal housing (IP65);
l Automated calculate the size of the flaw with w ide bottom type in AVG function.
l 6dB DAC functions;
l Provides high contrast viewing of the waveform from bright, direct sunlight to completae darkness and easy to read from all angles;
l Powerful pc software and reports can be export to excel;
Measuring Range and Measuring Error
Range of scanning: 0 mm ~10000 mm
Resolution for scanning: 0.1mm (2.5mm ~100mm)
1mm (100 mm ~10000mm)
Range of gain: 0dB ~120 dB
D-Delay: -20µs~+3400µs
P-Delay: 0µs~99.99µs
Sound speed : 1000 m/s~15000m/s
Specifications
Title
|
Parameter
|
Title
|
Parameter
|
Measuring Range(mm)
|
0 ~ 10000
|
Measurement Mode
|
Single,Dual,Thru
|
Vertical Linearity Error
|
≤3%
|
Reject
|
0~80%
|
Horizontal Linearity Error
|
≤0.1%
|
Pulse Displacement(μs)
|
-20 ~ +3400
|
Sensitivity Leavings
|
≥62dB
|
Zero(μs)
|
0.0 ~ 99.99
|
Dynamic range
|
≥34dB
|
Port Type
|
BNC / LEMO
|
Resolving Power
|
≥36dB
|
Operating Temperature (℃)
|
-20~50
|
Frequency Range(MHz)
|
0.5 ~ 15
|
H×W×D(mm)
|
240×156×50
|
Gain(dB)
|
0 ~ 120
|
Weight(kg)
|
1.0(with battery)
|
Material Velocity(m/s)
|
1000 ~ 15000
|
|
|
Operation Environment
Temperature: -20℃~50℃
Humidity: 20%~90%RH
Free of strong magnetic field and corrosion.
Standard Configuration
Designation
|
Quantity
|
Main unit
|
1
|
1.5A/9V power adaptor
|
1
|
probe connecting cable
|
2
|
Carrying case
|
1
|
Instruction manual
|
1
|
Straight probe
|
3/4” 2.5MHz (One)
|
Angle probe
|
8×9 60°4MHz (One)
|
Ying